Customization: | Available |
---|---|
Output Type: | Single Output |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | MS-35-5 | MS-35-12 | MS-35-15 | MS-35-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 6A | 3A | 2.4A | 1.5A | |
CURRENT RANGE | 0~6A | 0~3A | 0~2.4A | 0~1.5A | |
RATED POWER | 30W | 36W | 36W | 36W | |
RIPPLE & NOISE (max.) Note.2 | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75-5.5V | 10.8 ~ 13.2V | 13.5-16.5V | 22.6 ~ 26.4V | |
VOLTAGE TOLERANCE Note.3 | +2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 200ms 100ms 20ms at full load | ||||
INPUT | VOLTAGE RANGE | 180~260VAC 240-370VDC | |||
FREQUENCY RANGE | 47-63HZ | ||||
EFFICIENCY(Typ.) | 78% | 83% | 83% | 85% | |
AC CURRENT | 0.5A/230VAC | ||||
INRUSH CURRENT(max.) | COLD START 36A/230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60°C (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20~+85°C,10~95%RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | ||||
VIBRATION | 10~500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY& EMC |
SAFETY STANDARDS | Design refer to UL1012 | |||
WITHSTAND VOLTAGE | l/P-0/P:1.5KVAC l/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | l/P-O/P, l/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION &RADIATION | Design refer to FCC Parti 5 J Conduction Class B | ||||
OTHERS | MTBF | 408.3K hrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 84*58*38mm(L*W*H) | ||||
PACKING | 0. 17Kg;100pcs/18Kg/0.9CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |