Customization: | Available |
---|---|
Output Type: | Single Output |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | S-50-5 | S-50-12 | S-50-15 | S-50-24 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 10A | 4.2A | 3.4A | 2.1A | |
CURRENT RANGE | 0-10A | 0-4.2A | 0-3.4A | 0-2.1 A | |
RATED POWER | 50W | 50.4W | 51W | 50.4W | |
RIPPLE & NOISE (max.) Nott^ | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 475-5.5V | 10.8-13.2V | 13.5-16.5V | 22.6 - 26.4V | |
VOLTAGE TOLERANCE NotoJ | 12.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 200ms, 100ms, 20ms at full load | ||||
INPUT | VOLTAGE RANGE | 85 -132VAC /170 - 264VAC selected by switch 240-370VDC | |||
FREQUENCY RANGE | 47_63Hz | ||||
EFFICIENCY(Typ.) | 71% | 78% | 78% | 82% | |
AC CURRENT | 1.3A/115VAC 0.65A/230VAC | ||||
INRUSH CURRENT(max.) | COLD START 18A/115VAC 36A/230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed. | |||||
ENVIRONMENT | WORKING TEMP. | -10 - +60DC {Refer to output load derating curve) | |||
WORKING HUMIDmr | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDrTY | -20-+85°C,10-95% RH | ||||
TEMP. COEFFICIENT | ±0.03%°C(0-50°C) | ||||
VIBRATION | 10-500Hz, 2G lOmln./lcycle, period for 60mln. each alongX, Y, Zaxes | ||||
SAFETY&EMC | SAFETY STANDARDS | Design refer to UL1012 | |||
WITHSTAND VOLTAGE | l/P-0/P:1.5KVAC l/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | l/P-O/P, l/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Design refer to FCC Parti 5 J Conduction Class B | ||||
OTHERS | MTBF | 408_3Khrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 159*97*38mm (L*W*H) | ||||
PACKING | 0.51 Kg; 24pcs/13.1Kg/0.7CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 2bV of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : Includes set up tolerance, line regulation and load regulation. |