• SPD Surge Protective Breaker Device
  • SPD Surge Protective Breaker Device
  • SPD Surge Protective Breaker Device
  • SPD Surge Protective Breaker Device
  • SPD Surge Protective Breaker Device
  • SPD Surge Protective Breaker Device

SPD Surge Protective Breaker Device

Breaking Capacity: SPD
Operation: Manual Type
Speed: Fuse
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: SPD
Samples:
US$ 3/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SUP SPD
Poles Number
4
Type
SPD
Function
Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC
Transport Package
Carton
Trademark
ELECAL
Origin
Wenzhou

Product Description

Usage and application scope
SUP1 type surge protective device (short name "SPD") is suitable for AC 50/60 Hz,380V and the following electric power systems,such as TT, IT, TN-S, TN-C, TN-C-S. It protects the electric network shocked by the thunder or over voltage .
Working condition:
 1.Height: not more than 2000m 
 2. Operating temperature : normal -5~+40C Enlarge range: -40~+80C
 3. Relative humidity: on condition that room temperature 30%~90%
 4. Installed at no notability shocked and virated place
 5. Don't be contained in explosion medium,the medium such as air and dust (including conduction dust ) shouldn't come to the degree that can corrode metal or damage insulation.
Model and meaning
Tripping device
There's tripping device designed on the modular of the protector. When the protector is over heat or shocked, the tripping device can automatically separate it from the electric net, at the same time showing the indication signal. It's green when the protector is normal, red when tripping.
Remote signaling contact 
The products can be produced available with the accessory of remote signaling contact. If one or more of modular of the protector is in malfuction, the contact will be closed, and sending the malfunction signal.
Principal parameters 
Maximum continuous operating voltage : Uc  75   150  275  320  385  440  660V~
Test grade:II
Voltage protect level: Up< 350  550  1000   1250    1500   1750   2500V
Maximum discharge current : (8/20μS)   Imax    40kA 
Nominal discharge currrent: (8/20μS)    In   10    15    20kA
Remote communication terminal parameter 
Type of remote communication terminal
 
Active
Terminal normal power
UN/IN
AC: 250V/0.5A DC: 250V/0.1A, 125V/0.2A, 75V/0.5A
Conductor section
SUP1-40/4-150
Maximum single line: 1.5mm2
Main Structure and Operating Principle
In three-phase four- line system , three phase lines and one zero line are connected protective device to the earth cable . (figure 1 ) . In normal situation , the protective device is high resistance , when the over voltage brings for electric network shocked by thunder or other reasons , the protective device will rapidly transmit in ns , then lead the voltage into earth and protect the electric equipment . As the surge voltage through the protective device and after disappear it will recover to high resistance and not influence the normal operating. 
Technical Parameters :
Item
75
150
275
320
440
600
Maximum continuous operating voltage
Uc
75V~110V~
50V~200V~
275V~350V~
20V~420V~
440V~585V~
600V~1600V~
Nominal discharge currrent:
In
10
15
20
15
15
15
Maximum discharge current
Imax
40
40
40
40
40
40
Voltage protect level Up
5kA
≤350V
≤550V
≤1kV
≤1250V
≤1750V
≤2.5kV
In
≤450V
≤750V
≤1.5kV
≤1750V
≤2250V
≤3kV
Response time ns
≤25ns
Max. fuse intensity
125AgL/Gg
100AgL/Gg
Short circuit current intensity
50kA/50Hz
25kA/50Hz
Operating temperature area
40C ~+ 80C
Conductor section
Min 1.5mm?sibgle lead, max. 35mm multi-twisting lead/35mm single laed
Installation frame
35mm rail
Out case
red hot shrink material
Protection class
IP20
Dimension
one stnadard module width
Installation 
1. It is installed by standard 35 mm rail.
2. The earth cable should choose the double color wire 4mm?whose length is not longer than 500 mm.
3. To avoid the influence to the electric net after the protector is in malfuction, the protector connected to L line should be in series connect with a fuse. The appearance and installation dimension refer to the Fig. 3.
 
Adjustment, operation, maintenance
1. There's no need to adjust the protector after installation.
2. The protector can automatically protect the electric net should it's installed rightly.
3. When operating, check whether the modular scutcheon is red, at the same time check whether the indication red light is lighting, then can change the malfunction device.

SPD Surge Protective Breaker Device
SPD Surge Protective Breaker DeviceSPD Surge Protective Breaker DeviceSPD Surge Protective Breaker DeviceSPD Surge Protective Breaker Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
10
Year of Establishment
2014-04-28