Customization: | Available |
---|---|
Output Type: | Single Output |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | S-250-5 | S-250-7.5 | S-250-12 | S-250-13.5 | S-250-15 | S-250-24 | S-250-27 | S-250-48 | |
OUTPUT | DC VOLTAGE | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 40A | 30A | 20A | 17.8A | 16A | 10A | 8.9A | 5A | |
CURRENT RANGE | 0~40A | 0~225A | 0~20A | 0~17.8A | 0~16A | 0~10A | 0~8.9A | 0~5A | |
RATED POWER | 200W | 200W | 240W | 240.3W | 240W | 240W | 240.3W | 240W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |
VOLTAGEADJ. RANGE | 4.5 ~ 5.6V | 6~9V | 10 ~ 13.2V | 12 ~ 15V | 13.5-18V | 20-26.4V | 26 ~ 32V | 41 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 200ms, 100ms, 20ms at full load | ||||||||
INPUT | VOLTAGE RANGE | 90 ~ 132VAC /180 - 264VAC by switch 254-370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 74% | 79% | 80% | 80% | 81% | 83% | 83% | 84% | |
AC CURRENT | 6A/115VAC 3A/230VAC | ||||||||
INRUSH CURRENT (max.) | 50A/115VAC 50A/230VAC | ||||||||
LEAKAGE CURRENT | <3.5mA/240VAC | ||||||||
PROTECTION | OVER LOAD | 105 ~ 135% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVERVOLTAGE | 5.75-6.75V | 9.4-10.9V | 13.8 ~ 16.2V | 15.5 ~ 18.2V | 18 ~ 21V | 27.6 ~ 32.4V | 33.7 ~ 39.2V | 57.6 ~ 67.2V | |
Protection type: Shutdown o/p voltage, re-power on to recover | |||||||||
OVER TEMPERATURE | ^90°C(RTH3) Detect on inside ambient temperature | ||||||||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +50°C (Refer to output load derating curve) | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -20~+85°C,10~95%RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/°C(0~50°C) | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY& EMC |
SAFETY STANDARDS | Design refer to UL1950 | |||||||
WITHSTAND VOLTAGE | l/P-0/P:1.5KVAC l/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | l/P-O/P, l/P-FG, O/P-FG:100M Ohms/500VDC | ||||||||
EMI CONDUCTION &RADIATION | Design refer to FCC Parti 5 J Conduction Class A | ||||||||
OTHERS | MTBF | 271.9K hrs min. MIL-HDBK-217F(25°C) | |||||||
DIMENSION | 215*115*50mm(L*W*H) | ||||||||
PACKING | 0.93Kg;12pcs/12Kg/0.92CUFT | ||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |